Neo Rack (1000-10000VA)

Neo Rack (1000-10000VA)

On Line UPS

The range Neo Rack uses double conversion technology to provide clean, high level quality power to fully protect mission-critical devices such as communications networks, small computer centers, servers, telecoms applications and industrial applications.

 

Features

Technical Specifications

Product Brochure

Main features:

Wide input voltage range (110V-300V)

Neo Rack provides stable power to connected devices under unstable power environments.

Programmable power management outlets

With programmable power management outlets, users can easily and independently control load segments. During power failure, this feature enables users to extend battery time to critical loads by shutting down the non-critical devices.

ECO mode operation for energy saving

Offers efficiency up to 97% to reduce energy usage & cost. UPS supplies the loads via static bypass, timely returning to online double conversion when the need arises.

50/60 Hz Frequency Converter Mode

Lock output frequency at 50Hz or 60Hz to supply sensitive equipments.

Emergency Power Off (EPO) Function

This feature can secure the personnel and equipment in case of emergency.

Maintenance bypass available (Neo Rack 6Κ & 10Κ)

Internal maintenance bypass assures continuous power to critical devices during UPS maintenance.

Parallel System (Neo Rack 6K &10Κ)

Neo rack 6K & 10K models can be used in parallel operation with up to 3 units. This function increases power capacity, safety and availability.

DSP technology applied for Neo Rack 6K & 10K

A DSP controller provides an improved and cost-effective solution with high performance.

Smart battery charger design to optimize battery performance

The Neo Rack range is equipped with 2 or 3 stage charger designed to guarantee battery recharge time. Also, it adjusts charging voltage according to the temperature. These features extends the storage capacity and the life cycle of the batteries.

SNMP + USB + RS-232

The communication of the UPSP is done via the USB or RS-232 and also with SNMP interface.

 

MODELS

Neo

1K RACK

Neo

1.5K RACK

Neo

2K RACK

Neo

3K RACK

Neo

6K RACK

Neo

10K RACK

PHASE Single Phase Input / Single Phase Output
CAPACITY 1000VA / 800W 1500VA / 1200W 2000VA / 1600W

3000VA /

2400W

6000VA

/ 4800W

10000VA

/ 8000W

INPUT

Voltage Range Low Line Transfer 160 VAC ± 5% or 80 VAC ± 5% @ 100% load 176 VAC ± 3% @ 100% load
110 VAC ± 5% or 50 VAC ± 5% @ 50% load 110 VAC ± 3% @ 50% load
Low Line Comeback 175 VAC ± 5% or 85 VAC ± 5% @ 100% load 186 VAC ± 3% @ 100% load
120 VAC ± 3% @ 50% load
High Line Transfer 300 VAC ± 5 % or 150 VAC ± 5 % 300 VAC ± 3%
High Line Comeback 290 VAC ± 5 % or 145 VAC ± 5 % 290 VAC ± 3%
Frequency Range 40 Hz ~ 70 Hz 46~54 Hz or 56~64 Hz
Power Factor ≧ 0.99 @ nominal voltage (100% load) ≧ 0.99 @ 100%load

OUTPUT

AC Voltage Regulation (Batt. Mode) ± 3% ± 1%
Frequency Range (Synchronized Range) 47 ~ 53 Hz or 57 ~ 63 Hz 46~54 Hz or 56~64 Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio 3:1
Harmonic Distortion

≦ 3 % THD

(Linear Load)

≦ 4 % THD

(Linear Load)

≦ 3 % THD

(Linear Load)

≦ 6 % THD

(Non-linear Load)

≦ 7 % THD

(Non-linear Load)

≦ 6 % THD

(Non-linear Load)

Transfer Time AC Mode to Batt. Mode Zero
Inverter to Bypass 4 ms (Typical) Zero
Waveform (Batt. Mode) Pure Sinewave

EFFICIENCY

AC Mode 85% 88% 89%
Battery Mode 83% 88%
BATTERY
Battery Type 12 V / 7 Ah 12 V / 9 Ah 12 V / 7 Ah 12 V / 9 Ah 12 V / 7 Ah 12 V / 9 Ah
Numbers 3 3 6 6 20 20
Typical Recharge Time 4 hours recover to 90% capacity 7 hours recover to 90% capacity 9 hours recover to 90% capacity
Charging Current (max.) 1.0 A
Charging Voltage 41.0 VDC ± 1% 82.1 VDC ±1% 273 VDC ±1%

INDICATORS

LCD Panel UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions

ALARM

Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continuously sounding

PHYSICAL

Dimension, H x W x D 2U x 19′ x 420mm 3U x 19′ x 580mm UPS: 3Ux19′ x 580mm UPS : 3U x 19′ x 668mm
Battery Pack :

3U x 19′ x 580mm

Battery Pack :

3U x 19′ x 580mm

Net Weight (kgs) 16 17 29 31 UPS Unit : 17 UPS Unit : 20
Battery Pack : 57 Battery Pack : 63

ENVIRONMENT

Humidity 20-90 % RH @ 0- 40°C (non-condensing)
Noise Level      

COMMUNICATION

Smart RS-232/USB Supports Windows 98/2000/2003/XP/Vista/2008, Windows 7, Linux and MAC
Optional SNMP Power management from SNMP manager and web browser