facebook
Othonos 39, 17343
Agios Dimitrios Athens
Mon-Fri
09:00 - 17:00

Neo II 3/3 (10-80KVA)

Neo II 3/3 (10-80KVA)

On line UPS

UPS Neo ΙΙ 3/3 is a reliable solution signed by ACE Power Electronics.  The range Neo Pro 3P/3P uses double conversion technology to provide clean, high level quality power to fully protect mission-critical devices such as communications networks, small computer centers, servers, telecoms applications and industrial applications

 

Features

Technical Specifications

Product Brochure

DSP technology

A DSP controller provides an improved and cost-effective solution with high performance

Output power factor 1

For critical applications the online three-phase UPS with output power factor 1.0 ensures higher and upgraded performance.

Αctive power factor correction in each phase

The power factor correction is active at all periods and increases the input performance.

Double input

Neo II 3/3 is available optional and with double input for higher flexibility in system configuration.

50/60 Hz Frequency Converter Mode

Lock output frequency at 50Hz or 60Hz independently of the input frequency.

ECO mode operation for energy saving

Offers efficiency up to 99% to reduce energy usage & operation cost. UPS provides energy to the load via static bypass, timely returning to online double conversion when needed.

Emergency Power Off (EPO) Function

This feature can secure the personnel and equipment in case of emergency.

Configurable charging current

The user can select the charging current  through the LCD screen depending on the application.

Powerful charger

The Neo II 3/3 series has a built-in powerful charger with long-term support capabilities, when connected to a high-capacity external battery pack.

Flexible design for batteries

Τhe number of batteries is adjusted according to the power requirements. This feature allows the UPS to continue to operate even if some batteries are damaged.

Parallel operation with common batteries

The system can operate in parallel, increasing its power and efficiency. In addition, the parallel UPS system can operate with a common battery pack, resulting in the same performance at a lower cost.

*If the UPS is installed or used at an altitude higher than the maximum altitude there will be a degradation of the output power which will be 1% per 100m

MODELS 10Κ (L)* 15K(L) 20K(L)* 30K(L)* 40K(L) 60KL 80KL
PHASE   3 phase in / 3 phase out
POWER 10KVA/10KW 15KVA/15KW 20KVA/20KW 30KVA/30KW 40KVA/40KW 60KVA/60KW 80KVA/80KW
POSSIBILITY OF PARALLELISM   Up to 6 units in parallel

INPUT

Voltage   380/400/415 VAC (3Ph+N)
Range   -30% ~ +20%
Range   40~70Hz
Power Factor   ≥ 0.99 @ 100% Load
Distortion (THDi)   < 3% at full linear load

OUTPUT

Output Voltage   380/400/415 VAC (3ph+N)
AC Voltage Regulation (Batt. Mode)   ±1%
Frequency Range (Synchronized Range)   46~54Hz or 56~64Hz
Frequency Range (Batt. Mode)   50/60 Hz ± 1%
Crest Factor   3:1 (max)
Harmonic Duration   ≤ 1 % THD (Linear Load)
  ≤ 3 % THD (Non-linear Load)
Transfer Time

AC Mode to

Batt. Mode

  Zero
Inverter to Bypass   Zero
Waveform (Batt. Mode)   Ρossibility of Οverload
Ρossibility of Οverload   100-110 for 60 min, 111-125% for 10 min, 126%-150% for 1 min, >150% for 400ms

BYPASS

Nominal Voltage   380/400/415 VAC (3Ph+N)
Voltage Range   -30% ~ +20% (configurable)
Frequency Range (Synchronized Range)   46~54Hz or 56~64Hz

Possibility of

overload

  >130% 1 min (default)

Continuous operation until security activation (optional)

EFFICIENCY

AC Mode   96.0%
ECO mode   99.0%
Battery Mode   96.0%

BATTERIES

Standard Model Type 12 V / 9 Ah 12 V / 9 Ah 12 V / 9 Ah 12 V / 9 Ah 12 V / 9 Ah N/A N/A
Numbers (10+10) PCS (16+16) PCS (16+16) PCS (16+16) pcs x 2 strings N/A N/A
Typical Recharge Time 9  hours recover to 90% capacity N/A N/A
Charging Current (max.) 1Α ~ 12Α 1Α ~ 16Α(configurable) N/A N/A
Charging Voltage ±136.5 VDC ±10% ±218 VDC ±10% N/A N/A
Long-run Model Type   It depends the application
Numbers ±10 pcs ±16 pcs ~ ±20 pcs (configurable)
Charging Current (max.) 1Α ~ 12Α (configurable) 1Α ~ 16Α (configurable) 1Α ~ 12Α (configurable) 2Α ~ 32Α (configurable)
Charging Voltage ±13.65 VDC ±10% ±13.65 x N (N=16~20)

PHYSICAL

Standard Model Dimension Υ x Π x Μ (mm)     630x250x826     815x300x1000   Ν/Α
  Net Weight (kgs)   124 139 255 250    N/A  
Long-run Model Dimension ΜΧΠΧΥ (mm)     630x250x826     815x300x1000   790x360x1010
  Net Weight (kgs)   28 43 60 67 108 113

ENVIRONMENT

Temperature   0-40°C
Humidity   <95%, non-condensing
Level*   0 ~ 1500m full load
Noise level < 60dB @ 1 m < 63dB @ 1 m < 65dB @ 1 m

COMMUNICATION

Smart RS-232/USB   Supports Windows 2000/2003/XP/Vista/2008, Windows 7/8/10, Linux και MAC
SNMP   Power management from SNMP manager and web browser

 

 

 

 

 

 

 

 

 

Download the Pdf here

 

 