Home » Products » Energy Saving Systems » Voltage Optimisers » Ecostab-Ecobuck
Ecostab-Ecobuck
Energy Saving System
ECOSTAB-ECOBUCK is a voltage stabilizer designed for Energy Saving and capable of improving Power Quality in all mains voltage conditions.
Ecostab-Ecobuck supplies the load with a stable voltage having a value less than or equal to the nominal mains voltage.
The voltage with which the load is powered can be set through a potentiometer between the nominal value and -8%.
Ecostab-Ecobuck is able to increase or reduce the voltage of the electrical distribution network in order to provide the loads with an optimal voltage, which can be set to a desired value and kept stable.
The desired value is linearly adjustable between a minimum value of 368V (-8%) and a maximum value of 400V (± 0%).
In the entire range of variation of the mains voltage allowed by the standard (± 10% of the nominal value of 400V) the load is always powered by the Ecostab-Ecobuck at the desired voltage, kept stable at ± 1%.
The variations of the mains voltage both in excess and in default are compensated and the supply voltage to the load is kept stable at the set value.
Range. Voltage optimisers are available in power range from 5 to 4000 KVA, in single-phase and three-phase version.
Accuracy. Ecostab-Ecobuck voltage optimisers secure the true RMS voltage value with an accuracy of ±1% according to the presence of high harmonic distortions of the mains.
Regulation speed. An innovative control circuit combines an extremely fast regulation speed, from 11 to 33 ms/V according to the model, with the structural reliability of the electrodynamic system.
Overload capacity. This is a peculiarity of the Ecostab-Ecobuck electrodynamic regulation system. These devices can withstand overloads up to ten times the rated power for ten milliseconds, five times the rated power for six seconds or twice the rated power for one minute without damage.
Efficiency. Efficiency up to 98.5% at full load.
Power factor and load variation insensitivity. The adopted operating principle ensures that the accuracy and the regulation speed features of Ecostab-Ecobuck voltage optimisers remain unaltered under any load condition (full load or no load, with inductive or capacitive loads).
Frequency variation insensitivity. The control circuit works correctly also with mains frequency variations up to ± 5%.
Harmonic distortions. The high quality and correct use of materials ensure that the harmonic distortion is always maintained within 0.1% in any operating condition.
Impedance. The installation of an Ecostab-Ecobuck voltage optimiser in a pre-existing system does not require a new calculation of the protections because the internal impedance of the optimiser, varying from 0.52 to 0.015 Ohm, does not significantly affect the line impedance.
Operating temperature. Ecostab-Ecobuck voltage optimisers are designed to work correctly at a maximum ambient temperature of 40°C in the most demanding conditions: continuous operation, full load and minimum input voltage. Models suitable for operation at temperatures higher than 40°C are manufactured on request.
Degree of protection. According to the ambient conditions, the safety requirements and the installation site, Ecostab-Ecobuck voltage optimisers are available in 4 versions with the following protection degree: IP00, IP21, IP54 INDOOR and IP54 OUTDOOR.
Reliability. The MTBF exceeding 500,000 hours is the result of continuous improvement in technical aspects and production process.
Cooling system. Ecostab-Ecobuck voltage optimisers are cooled in different manner according to the type of casing and the ambient conditions by means of:
Installation. It is rather quick and easy. The voltage optimiser is installed after the energy counter and before the electric users.
Special versions. Ecostab-Ecobuck voltage optimisers can be equipped on demand with special fittings in separate cabinet, like e.g.: maintenance by-pass, thermal magnetic circuit breakers, insulating transformer, surge suppressors, lightning arresters, harmonic filters.
Remote control. Ecostab-Ecobuck voltage optimiers can be equipped with a special optional monitoring system POWER METER permitting the remote control via ETHERNET, INTERNET, GSM/GPRS. The following electric and physical parameters are detected: frequency, active power, reactive power, apparent power, distorting power, three-phase equivalent current, line current, power factor, active, reactive and inductive energy, harmonics, temperature, humidity, switch and contactor state. By using the POWER MANAGEMENT software installed on a non-dedicated PC, detected values can be managed and statistics can be obtained on a daily, weekly, monthly and yearly basis with various viewing, data processing, cost calculation and energy saving possibilities.
Compliance with standards. Ecostab-Ecobuck voltage optimisers comply with the following Directives:
M2..S Single- phase 230V 50-60 Hz- IP21 | |||||||
Model | Rated Power (KVA) | Input Voltage Variation (±%) | Output regulation range (%) | Response Time (ms/V) | Output accuracy (±%) | Dimensions AxBxH (mm) | Net weight (kg) |
M208EJ8S | 8 | 10 | 0 to -8 | 21 | 1 | 600x350x290 | 45 |
M210EJ12S | 12 | 21 | 800x450x400 | 65 | |||
M211EJ20S | 20 | 22 | 80 | ||||
M212EJ25S | 25 | 27 | 120 |
Y3..S Three- phase +N 400V 50/60 Hz -IP21 | |||||||
Model | Rated Power (KVA) | Input Voltage Variation (±%) | Output regulation range (%) | Response Time (ms/V) | Output accuracy (±%) | Dimensions AxBxH (mm) | Net weight (kg) |
Y308EJ20S | 20 | 10 | 0 to -8 | 13 | 1 | 350x580x890 | 120 |
Y310EJ40S | 40 | 12 | 450x800x1200 | 210 | |||
Y311EJ60S | 60 | 16 | 240 | ||||
Y312EJ80S | 80 | 19 | 290 | ||||
Y313AJ100S | 100 | 17 | 650x650x1800 | 480 | |||
Y314AJ150S | 150 | 27 | 1100x650x1800 | 620 | |||
Y316AJ200S | 200 | 19 | 650 | ||||
Y317AJ300S | 300 | 22 | 750 | ||||
Y318AJ400S | 400 | 16 | 1100x900x1900 | 1100 | |||
Y319AJ600S | 600 | 17 | 1100x1270x1800 | 1360 | |||
Y320AJ800S | 800 | 18 | 1100x1270x1900 | 1770 | |||
Y320AJ1000S | 1000 | 18 | 100x1270x1900 | 1850 | |||
Y322AJ1250S | 1250 | 26 | 2130x1350x2150 | 2700 | |||
Y323AJ1600S | 1600 | 18 | 3100 | ||||
Y324AJ2000S | 2000 | 17 | 3400 | ||||
Y326AJ2300S | 2300 | 18 |
3 cabinets 1100x1270x1900 |
3800 | |||
Y328AJ2500S | 2500 | 24 | 5200 | ||||
Y330AJ2800S | 2800 | 26 | 5700 |
ECOBUCK M Single- phase 230V 50-60 Hz- IP21 | |||||||
Model | Rated Power (KVA) |
Input Voltage Variation (± %) |
Output regulation range (%) | Response Time (ms/V) | Output accuracy (±%) | Dimensions AxBxH | Net weight (kg) |
Μ204EJB5S | 5 | +10% -8% | 0 έως -8% | 42 | ±1% | 450x560x430 | 45 |
M206EJB10S | 10 | 42 | 65 | ||||
Μ208EJB15S | 15 | 44 | 450x560x430 | 80 | |||
M210EJB30S | 30 | 54 | 120 |
ECOBUCK Y Three- phase 400 VAC +N 50/60Hz – IP21 | |||||||
Model | Rated Power (KVA) |
Input Voltage Variation (± %) |
Output regulation range(%) | Time (ms/V) | accuracy (±%) | Dimensions AxBxH | Net weight (kg) |
Y304EJB15SS | 15 | +10 -8% | 0 έως -8 | 26 | ±1% | 350x580x890 | 150 |
Y308EJB30SS | 30 | 24 | 210 | ||||
Y306EJB35SS | 45 | 26 | 450x800x1200 | 240 | |||
Y310EJB80SS | 80 | 24 | 290 | ||||
Y311EJB120SS | 100 | 32 | 650x650x1800 | 480 | |||
Y312EJB160SS | 150 | 40 | 1100x650x1800 | 560 | |||
Y313AJB200SS | 200 | 34 | 630 | ||||
Y314AJB300SS | 300 | 54 | 780 | ||||
Y316AJB400SS | 400 | 38 | 1100x900x1900 | 1100 | |||
Y317AJB600SS | 600 | 44 | 1360 | ||||
Y318AJB800SS | 800 | 32 | 1100x1300x1900 | 1770 | |||
Y319AJB1000SS | 1000 | 34 | 1100x1300x1900 | 1850 | |||
Y319AJB1250SS | 1250 | 34 | 1500x1350x2150 | 2700 | |||
Y320AJB1600SS | 1600 | 36 | 2150x1350x2150 | 3100 | |||
Y320AJB2000SS | 2000 | 36 | 2150x1350x2150 | 3400 | |||
Y322AJB2500SS | 2500 | 52 |
3 cabinets 1100x1300x1900 |
4600 | |||
Y323AJB3200SS | 3200 | 36 | 5200 | ||||
Y324AJB4000SS | 4000 | 34 | 6000 |