Home » Products » Solar Inverters » Hybrid Inveters » Hybrace
The Inverter HYBRACE is a multiply solution that covers the needs of different types photovoltaic systems. The Inverter HYBRACE has inputs for: Photovoltaic Panels, Batteries, loads and the main. The operation of hybrid inverter is programmable and gives priority to energy sources.
In case that the energy produced is larger than the requested then it is injected into the grid. HYBRACE Inverters are capable to cover the needs in terms of energy of buildings and installations.
Model |
HYBRACE 3KW | |||||
Nominal Power |
3000W | |||||
GRID-TIE OPERATION |
||||||
PV INPUT (DC) |
Maximum DC Power | 3200W | ||||
Nominal DC Voltage / Maximum DC Voltage | 360 VDC / 500 VDC | |||||
Start-up Voltage / Initial Feeding Voltage | 116 VDC / 150 VDC | |||||
MPP Voltage Range | 250 VDC ~ 450 VDC | |||||
Number of MPP Trackers / Maximum Input Current | 1 / 1 x 13 A | |||||
GRID OUTPUT (AC) |
Nominal Output Voltage | 208/220/230/240 VAC | ||||
Output Voltage Range | 184 – 264,5 VAC | |||||
Nominal Output Current | 13,1 A | |||||
Power Factor | > 0,99 | |||||
EFFICIENCY |
Maximum Conversion Efficiency (DC/AC) | 96% | ||||
European Efficiency@ Vnominal | 95% | |||||
OFF-GRID OPERATION |
||||||
AC INPUT |
AC Start-up Voltage/Auto Restart Voltage | 120-140 VAC / 180 VAC | ||||
Acceptable Input Voltage Range | 170 – 280 VAC | |||||
Maximum Input Current | 25 A | |||||
PV INPUT (DC) |
Maximum DC Voltage | 500 VDC | ||||
MPP Voltage Range | 250 VDC ~ 450 VDC | |||||
Number of MPP Trackers / Maximum Input Current | 1 / 1 x 13 A | |||||
OUTPUT (AC) BATTERY MODE |
Nominal Output Voltage | 208/220/230/240 VAC | ||||
Output waveform | Ημιτονική | |||||
Efficiency (DC to AC) | 93% | |||||
HYBRID OPERATION |
||||||
PV INPUT (DC) |
Nominal DC Voltage / Maximum DC Voltage | 360 VDC / 500 VDC | ||||
Start-up Voltage / Initial Feeding Voltage | 116 VDC / 150 VDC | |||||
MPP Voltage Range | 250 VDC ~ 450 VDC | |||||
Number of MPP Trackers /Maximum Input Current | 1 / 1 x 13 A | |||||
GRID OUTPUT (AC) |
Nominal Output Voltage 208/220/230/240 VAC | 208/220/230/240 VAC | ||||
Output Voltage Range | 184 -264,5 VAC | |||||
Nominal Output Current | 13,1 A | |||||
AC INPUT |
AC Start-up Voltage/Auto Restart Voltage | 120-140 VAC / 180 VAC | ||||
Acceptable Input Voltage Range | 170-280 VAC | |||||
Maximum AC Input Current | 25A | |||||
OUTPUT (AC) BATTERY MODE |
Nominal Output Voltage | 208/220/230/240 VAC | ||||
Efficiency (DC to AC) | 93% | |||||
BATTERY & CHARGER |
Nominal DC Voltage | 48 VDC | ||||
Maximum Charging Current | 25 A | |||||
GENERAL |
||||||
PHYSICAL |
Dimension, D x W x H (mm) | 170 x 415 x 420 | ||||
Net weight (Kgr) | 15.5 | |||||
INTERFACE |
Communication | RS-232/USB (Optional SNMP, Modbus, AS-400) | ||||
ENVIRONMENT |
Humidity | 0 ~ 90 % RH (Non condesing) | ||||
Operating temperature | 0 to 40° C | |||||
Altitude | 0 ~ 1000 m |