Next Energy 250 – 400KVA

Next Energy 250 – 400KVA

On Line UPS

Riello UPS Introduces NextEnergy, the latest UPS series designed for mission critical applications. The three phase UPS offers transformerless double conversion technology VFI SS 111, with integrated IGBT three-level design.

Features

Technical Specifications

Product Brochure

Main features:

Riello UPS Introduces NextEnergy, the latest UPS series designed for mission critical applications. The three phase UPS offers transformerless double conversion technology VFI SS 111, with integrated IGBT three-level design. NextEnergy is designed to meet the power requirements of tomorrow, offering high efficiency and low running cost. Thanks to the Efficiency Control System, NextEnergy also guarantees the highest levels of efficiency even at partial loads. Its unity power factor and easy system upgrading make it the ideal solution for the business continuity of any IT application. Zero impact source NextEnergy is designed with the latest technology to not only prevent disturbances on the mains but clean the power e.g.. Harmonics generated by non-linear loads.

The input AC/DC converter is based on the IGBT rectifier design using the latest 3-level technology. The key features are:

  • input current distortion < 3%
  • input power factor 0.99
  • power walk-in function that ensures progressive rectifier start-up
  • start-up delay function, to restart the rectifiers when mains power is restored.

Thanks to the programmable maximum input power (kW or kVA), NextEnergy can be installed into AC supply systems with limited power availability such as a diesel generator or contractually reduced power sources, andthen supply the additional power required using the batteries (peak demand function). Outstanding performances

  • The latest technology of NextEnergy and the careful selection of high-quality components help to achieve first-class performance such as unity power factor (kW/kVA) and the capability to supply capacitive loads, which are very common in most Data Centres, without any power derating up to 40 °C.
  • Outstanding system efficiency up to 97% in on-line double conversion mode, increasing to 99% in stand-by mode or smart-active.
  • The unit design adopts the forced ventilation method to extract the heat produced by the internal components. Specific attention has been given to the ventilation system to ensure the best operational level and lifetime.

This is thanks to the automatic speed control which constantly adjusts to the specific load level, the fan failure alarm and the fan redundancy – with condition apply.

Battery care system

The battery is one of the most important parts of the UPS that ensures the correct operation in case of mains failure. NextEnergy includes all the latest features to prolong the battery life and keep the battery working efficiently, as well as advising users about any potential problem. The variety of charging methods allows the use of the most common type of battery and technologies available on the market such as VLRA, AGM, GEL, NicCd etc. In addition to the flexibility of the battery cells, NextEnergy allows users to choose the most cost-effective solution for the required back-up time. The battery charging and discharging is assured by the STEP-UP/ STEP-DOWN converter which means that when the batteries are charged and the mains is available, the converter is no longer connected to the supply. This means the ripple current is practically zero which leads to a significant improvement in battery life.

Operation without Neutral

NextEnergy can work with or without the neutral connection. This is an important feature to reduce the TCO of the distribution system where the neutral is created by an isolation transformer close to the load. For example, in the modern Data Centre, or where the neutral is not used at all. The major benefit being a reduced cost of the distribution arrangements.

Easy installation

  • The small footprint of the cabinet and complete front access for all maintenance activities, ensures maximum space for installation and service.
  • NextEnergy includes top and bottom cable entry as standard, removing the need for large and costly top entry cabinets.
  • Ventilation is from the front to the top so no additional rear clearance required.

Maximum reliability and availability

NextEnergy UPS can be connected in parallel with up to 8 units to increase the capacity or add redundancy (N+1). Considering that a typical load can vary from 20 to 80%, the Efficiency Control System (ECS) function optimises the operating efficiency of the entire system according to the power absorbed by the load. This ensures higher overall efficiency during all load conditions. Hot System Expansion (HSE) allows the addition of further UPS into an existing system, without the need to switch off the operational units or transfer them to bypass mode. This guarantees maximum load protection, even during maintenance and system expansion. It ensures maximum levels of availability – even in the event of an interruption to the parallel control cable the system is “FAULT TOLERANT”. It is not affected by connection cable faults and continues powering the load without disruption, signaling an alarm condition.

Interactive Touch Screen

NextEnergy is equipped with a Touch screen 7” graphic display (800×480 pixels) providing UPS information, measurements, voltage and current waveforms, operating states and alarms in different languages. The default screen displays the UPS status, graphically indicating the status of the various assemblies (rectifier, batteries, inverter, bypass). Also, the panel is used for configuration and setting the parameters of the UPS with 3 levels of the security password.

Advanced Communication

NextEnergy offers the capability to work with the advanced multi-platform communications for all the latest operating systems and network environments.

  • PowerShield3 monitoring and shutdown software included for Windows operating systems 10, 8, 7, Hyper-V, 2016, 2012, and previous versions, Mac OS X, Linux, VMWare ESXi, Citrix XenServer and other Unix operating systems.
  • Compatible with PowerNetGuard remote monitoring service.
  • 2 slots for the installation of the optional communication accessories such as network adapters and BMS interface.
  • Ethernet and USB ports.
  • Relay cards with customized alarms and commands.

MODELSNXE 250NXE 300NXE 400
INPUT 
Nominal Voltage380-400-415 VAC three phase
Voltage tolerance  +20% -40% (with restrictions)
Frequency45-65 Hz
Power factor0,99
THDI [%]<3%
Soft Start 0-100% in 120 sec (selectable)
Standard equipment providedBack feed protection, separate bypass line
BATTERIES  
Type VRLA AGM / GEL, NiCd, Supercaps, Lion, Flywheels 
Ripple current Zero 
Recharge voltage compensation-0.11Vx° C
OUTPUT 
Nominal power (KVA)250300400
Active power (KW)250300400
Number of phases 3+Ν
Nominal Voltage 380-400-415 VAC Three plage + N
Static Stability  ±1%
Dynamic stability  ±5% in 10ms 
Voltage distortion<1% with linear load/<3% with non- linear load 
Frequency stability on battery ±0,05%
Frequency 50 or 60 Hz (selectable)
Overload 110% for 60′; 125% for 10′;150% for 20 seconds110% for 60′; 125% for 10′;150% for 1 minute
BY PASS 
Nominal voltage380-400-415 VAC three phase +N
Nominal frequency 50 or 60 Hz (selectable)
Frequency tolerance ± 2% (selectable from ± 1% to 5 %)
INFO FOR INSTALLATION 
Weight (kg)6348001100
Dimensions (WxDxH) (mm)800 x 850 x 19001200 x 850 x 19001400 x 850 x 1900 
Input cable Bottom Top and Bottom Top and Bottom
Remote signals Volt-free contract (configurable)
Remote Controls EPO, bypass and another spare 
CommunicationsUSB + Dry contacts +2 Slots for communication interface 
Operating temperature0 ° C/ +40 ° C
Relative humidity5 to 95% non-condensing
ColourDark grey RAL 7016
IP Rating IP 20 (other on request)
Efficiency (AC-AC) – On Line Mode up to 97%
StandardsSafety: EN 62040 -1 (directive 2014/35/UE); EMC: EN 62040 -2 (directive 2014/30UE)
Classification in accordance with IEC 62040-3(Voltage Frequency Independent) VFI – SS- 111