Multi Sentry (10-200 kVA)

Multi Sentry (10-200kVA)

On Line UPS

The Multi Sentry series is ideal for protecting data centres and telecommunications systems, IT networks and critical systems in general, where the risks connected with poor energy supply can compromise the continuity of activities and services. The Multi Sentry series is available in 10-12-15-20 kVA models with three- phase/single-phase input and single-phase output, and 10-12-15-20 kVA models with three-phase input and output and on-line double conversion technology in accordance with VFI-SS-111 classification (as set out in standard IEC EN 62040-3). Multi Sentry is designed and built using state-of-the-art technology and components. It is controlled

by a DSP (Digital Signal Processor) microprocessor, to provide maximum protection to the powered loads with no impact on downstream systems, and optimised energy savings.

Features

Multi Sentry (10-20kVA)

Multi Sentry (30-200kVA)

Product Brochure

Main features:

Zero impact source
Multi Sentry solves installation problems in systems where the power supply has limited power available, where the UPS is supported by a generator or where there are compatibility problems with loads that generate harmonic currents; Multi Sentry has a zero impact on its power source, whether this is the mains power supply or a generator:

  • input current distortion < 3%
  • input power factor 0,99
  • power walk-in function that ensures progressive rectifier start up
  • start-up delay function, to restart the rectifiers when mains power is restored if there are several UPS in the system.

In addition, Multi Sentry plays a filtering and power factor correction role in the power network upstream of the UPS, as it eliminates harmonic components and reactive power generated by the power utilities.

 Installation flexibility
MSM /MST 10,12,15,20 is available in two different cabinet frames:

  • 1320mm high housing: batteries to for back up time up to thirty minutes on 20 kVA or Isolation transformer;
  • 930 mm high compact version which secure the UPS range features in an extremely reduced size;

The single phase output (MCM/MSM 10, 12, 15, 20 KVA) thanks to Its highly flexible design allows full compatibility with both three-phase and single-phase power supplies, thus eliminating problems in connecting the UPS to the system.

Battery care system
Proper battery care is critical to ensuring correct UPS operation in emergency conditions. The Riello UPS battery care system consists of a series of features and capabilities to optimise battery management and obtain the best performance and operating life possible. Battery recharging: Multi Sentry is suitable for use with hermetically sealed lead-acid (VRLA), AGM and GEL batteries and Open Vent and Nickel Cadmium batteries. Depending on the battery type, different charging methods are available:

  • One-level voltage recharge, typically used for widely available VRLA AGM batteries
  • Two-level voltage recharge according to IU specification
  • Charge blocking system to reduce electrolyte consumption and lengthen the life of VRLA batteries.

Recharge voltage compensation based on temperature in order to prevent excessive battery charges or overheating.

Battery tests to diagnose in advance any reduction in performance or problems with the batteries. Deep discharge protection: during extended low-load discharges, the end-of-discharge voltage is increased – as recommended by battery manufacturers – to prevent damage or reduced battery performance. Ripple current: recharge ripple current (residual AC component) is one of the main causes of reduced reliability and battery life. Using a high frequency battery charger, Multi Sentry reduces this value to negligible levels, prolonging battery life and maintaining high performance over a long period of time. Wide voltage range: the rectifier is designed to operate within a wide input voltage range (up to – 40% at half load), reducing the need for battery discharge and thus helping to extend battery life.

Maximum reliability and availability
Distributed parallel configuration of up to 8 units per redundant (N + 1) or power parallel system. The UPS continue to operate in parallel even if the connection cable is interrupted (Closed Loop).

 Operation flexibility
The compact version of the Multi Sentry (MCM/MCT 10, 12, 15, 20 KVA) features embedded auxiliary outlet s for intelligent utilities supply. The “energy share” outlet is driven by relays which are customizable depending on the installation or customer needs, making it more suitable for protecting different critical load.

On the MSM/MST Multi Sentry version the same functionality is available as optionally.

Advanced communications
Multi Sentry is equipped with a back-lit graphic display (240×128 pixels) providing UPS information, measurements, operating states and alarms in different languages. It can also display wave forms and voltage/ current forms. A wide range of comunications options are available to ensure global and comprehensive UPS monitoring.

 

MODELSMCM/MSM
10
MCM/MSM   12MCM/MSM
15
MCM/MSM
20
MCT/MST
10
MCT/MST
12
MCT/MST
15
MCT/MST
20

INPUT

Nominal Voltage380-400-415 VAC three-phase + N / 220-230-240 Vac
single-phase + N
380-400-415 VAC three-phase + N
Nominal frequency50/60 Hz
Frequency tolerance40 – 72 Hz
Power factor at full load0,99
Current distortionTHDI ≤ 3%

BY PASS

Nominal voltage220-230-240 VAC single-phase + N380-400-415 VAC three phase + N
Number of phases13 + N
Voltage tolerance (Ph-N)180 – 264 V (selectable)
Nominal frequency50 or 60 Hz (selectable)
Frequency tolerance±5 (selectable)
Bypass overload125% for 60 minutes, 150% for 10 minute

OUTPUT

Nominal power (kVA)1012152010121520
Active power (kW)910,813,518910,813,518
Power factor0,9
Number of phases13 + N
Nominal voltage (V)220-230-240 VAC single-phase + N (selectable)380-400-415 VAC three-phase + N (selectable)
Static variation± 1%
Dynamic variation± 3%
Crest factor3 : 1 Ipeak/Irms
Voltage distortion≤ 1% with linear load / ≤ 3% with non-linear load
Frequency50/60 Hz
Frequency stability during
battery operation
0,01%

BATTERIES

TypeVRLA AGM/GEL/NiCd/Li-ion
Recharge Time6 hours

INFO FOR INSTALLATION

Weight without batteries (kg)
(MCM/MSM)
80/10582/11090/11595/12080/10582/11090/11595/120
Dimensions (WxDxH) (mm)320 x 840 x 930 (MCM/MCT version) / 440 x 850 x 1320 (MSM/MST version)
Communications 3 slots for communications interface / USB / RS232
Operating temperature0 – 40 ° C
Relative humidity90% non-condensing
ColourDark grey RAL 7016
Noise level at 1 m [dBA ±2]
Smart Active
< 40 dBA
IP ratingIP20
Smart Active efficiencyup to 98%up to 99%
StandardsEuropean Directives: L V 2006/95/CE low voltage Directive
EMC 2004/108/CE electromagnetic compatibility Directive
Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2 C2
Classification in accordance with IEC 62040-3 (Voltage Frequency Independent) VFI – SS – 111
Moving the UPScastors / transpallet (10 – 20 kVA)

MODELSMST 30MST 40MST 60MST 80MST 100MST 125MST 160MST 200

INPUT

Nominal Voltage 380-400-415 VAC three-phase + N
Nominal frequency50/60 Hz
Frequency tolerance40 – 72 Hz
Power factor at full load0,99
Current distortion THDI ≤ 3%THDI ≤ 2,5%

BY PASS

Nominal voltage380-400-415 VAC three-phase + N
Number of phases3 + N
Voltage tolerance (Ph-N)180 – 264 VAC (selectable)
Nominal frequency50 or 60 Hz (selectable)
Frequency tolerance±5 (selectable)
Bypass overload125% for 60 minutes, 150% for 10 minute

OUTPUT

Nominal power (kVA)30406080100125160200
Active power (kW)2736547290112,5160200
Power factor0,91
Number of phases3 + N
Nominal voltage (V)380-400-415 VAC three-phase + N (selectable)
Static variation± 1%
Dynamic variation± 3%
Crest factor3 : 1 Ipeak/Irms
Voltage distortion≤ 1% with linear load / ≤ 3% with non-linear load
Frequency50/60 Hz
Frequency stability during
battery operation
0,01%

BATTERIES 

TypeVRLA AGM/GEL/NiCd/Li-ion/Supercaps
Recharge Time 6 hours

INFO FOR INSTALLATION

Weight without batteries (kg)135145190200220250450460
Dimensions (WxDxH) (mm)440 x 850 x 1320500 x 850 x 1600650 x 840 x
1600
850 x 1050 x 1900
Communications 3 slots for communications interface / USB / RS232
Operating temperature0 – 40 ° C
Relative humidity 90% non-condensing
Colour Dark grey RAL 7016
Noise level at 1 m [dBA ±2]
Smart Active
< 40 dBA< 63 dBA< 50 dBA
IP ratingIP20
Smart Active efficiencyup to 99%
Standards European Directives: L V 2006/95/CE low voltage Directive
EMC 2004/108/CE electromagnetic compatibility Directive
Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2 C2
Classification in accordance with IEC 62040-3 (Voltage Frequency Independent) VFI – SS – 111
Moving the UPScastors (30 – 200 kVA)