Othonos 39, 17343
Agios Dimitrios Athens
Mon-Fri
08:30 - 16:30
+30 2109966555
+30 2109969444

Stabilux

Stabilux
Luminous Flux Regulators 

STABILUX

luminous flux regulators

constitute the most complete range available on the market today. Four series of regulators are available to satisfy the requirements of each single plant, and guarantee a return on investment in line with the requirements of the various users.

The proposal consists of more than seventy standard models available in single and three-phase versions.

Three main series have been developed to meet the different requirements:

EMR for low power

lighting plants

. Four single-phase models available for power ratings from 3.5 to 15 kVA.

 
TMR for small lighting plants. Available for power ratings from 10,5 to 45 kVA.

PMR specific for public lighting plants. 48 three-phase models available for power ratings from 9 to 65 kVA.

PMT suitable for lighting applications in which “safety and saving” are essential, integrating natural light with artificial light.

All versions are provided with

smart control

using microprocessor technology, capable of commanding and controlling at the same time the plants connected.

STABILUX models can be integrated in a remote control and remote management systems to obtain the maximum advantages in terms of saving and running costs. By changing the software of the regulator, different performances can be obtained while the hardware remains unaltered. All the flux regulators have a modular design facilitating maintenance and servicing.

Product Brochure

Technical Specifications


Product Brochure 

 

Download the Pdf here

 

 

Technical Data EMR

EMR series – Technical data

Nominal input voltage230V 1ph+N 50/60 Hz
Input voltage variationsfrom 183 to 242 Volt
Nominal output voltage230 V RMS
Output voltage accuracy±1%
Admitted load variationsfrom 0 to 100%
Stabilization speed20ms/Volt
Voltage regulation speed6 Volt/min
Lamp ignition voltageselectable from 202 to 230 Volt via switch
Ignition cycle duration 6 min6 min

Operating voltage at underpower conditions available on three levels:

1) minimum level Vrid selectable from 175 to 202 Volt via switch
2) first intermediate level supplying a voltage Vr1=Vrid+(Vnom-Vrid)
3) second intermediate level supplying a voltage Vr2=Vnom-(Vnom-Vrid)/3 

 

Note: the two intermediate levels cannot be clock controlled

 

Waveform distortion higher than 97%
Efficiency> 97%
Operating temperaturefrom -20 to +35°C
Coolingnatural air cooled
Technichal Data TMR

ΤMR series – Technical data

Nominal input voltage 

3x230V 3ph+N

Input voltage variations 

from 183 to 242 Volt

Nominal output voltage 

3 Χ 230V RMS 3ph+N

Output voltage accuracy 

±1%

Admitted load variations

from 0  to 100%

Stabilization speed 

20 ms/Volt

Voltage regulation speed 

6 Volt/min

Load Power factor

Any

Lamp inguition voltage 

Selectable from 202 to 230 via microprocessor

Operating voltage at underpower conditions

Selectable from 183 – 200 V in each phase
Waveform distortion < 0,2% in any operating condition
Efficiency > 96%

Operating temperature

-20 from + 35 ° C

Cooling 

natural air cooled

Protection degree 

IP 00-54,depending on the versions

Isolation class 

I

Technical data PMR
PMR series – Technical data
Nominal input voltage3x230V 3ph+N
Input voltage variationsfrom 183 to 253 Volt
Nominal output voltage 3 Χ 230V RMS 3ph+N
Output voltage accuracy ±1%
Admitted load variations from 0 to 100%
Stabilization speed 40 ms/Volt
Voltage regulation speed 6 Volt/min
Load Power factor Any
Lamp ignition voltage selectable from 202 to 230 Volt via microprocessor control
Parameters programmable by the user: • operating voltages: 6 values per day for each day of the week, for each of the 6 week models
• lamp ignition voltage
• operating voltages at underpowered conditions
• operating voltages at nominal conditions
• transition speed from one operating cycle to the other
• ignition cycle duration
• line drop compensation voltage
• alarm intervention time
Waveform distortion less than 0,2% in any operating condition
Efficiency > 97%
Operating temperaturefrom -20 to +35°C
Coolingforced
Storage temperatureIP 00-21-54 depending on the versions
Isolation classI

Technical data PMΤ
PMΤ series – Technical data 
Nominal input voltage3x230V 3ph+N
Input voltage variationsfrom 183 to 253 Volt
Nominal output voltage 3 Χ 230V RMS 3ph + N
Output voltage accuracy ±1%
Admitted load variations from 0 to 100%
Stabilization speed 40 ms/Volt
Voltage regulation speed 6 Volt/min
Load Power factor any
Lamp ignition voltage Selectable between 202 and 230 Volt through microprocessor control
Parameters programmable by the user:• min./max threshold values to switch on/off the reinforcement circuits (max. 6)
• lamp ignition voltage
• operating voltage with minimum threshold Smin
• operating voltage with maximum threshold Smax
• duration of ignition cycle
• line drop compensation voltage
• alarm intervention time
Waveform distortion Less than 0.2% in any operating condition
Efficiency > 97%
Operating temperature-20 to + 35 ° C
Cooling Forced
Protection degree IP21
Isolation class I